● Integrated design of air supply channel and refrigeration unit.
● Large size observation window makes it convenient for operator to observe the test sample inside the chamber.
● The inner chamber is made by SUS304 stainless steel; the external chamber is made by two-sided galvanized steel sheet and its surface is treated by electrostatic plastic spraying.
● The refrigerating system, waterway system and the electrical control system of the chamber have been modularized, placed separately and are safe and reliable.
● Intelligent control of refrigeration system applies to large range of load and the running power is lower
Model a | FPTH 64-20A |
FPTH 300-20A |
FPTH 500-20A |
FPTH 1000-20A |
FPTH 64-40A |
FPTH 300-40A |
FPTH 500-40A |
FPTH 1000-40A |
FPTH 64-70A |
FPTH 300-70A |
FPTH 500-70A |
FPTH 1000-70A |
||
Internal Volume ( L ) | 64 | 300 | 500 | 1000 | 64 | 300 | 500 | 1000 | 64 | 300 | 500 | 1000 | ||
Inner Dimension ( mm ) | W | 400 | 700 | 800 | 1000 | 400 | 700 | 800 | 1000 | 400 | 700 | 800 | 1000 | |
H | 400 | 700 | 900 | 1000 | 400 | 700 | 900 | 1000 | 400 | 700 | 900 | 1000 | ||
D | 400 | 600 | 700 | 1000 | 400 | 600 | 700 | 1000 | 400 | 600 | 700 | 1000 | ||
Outer Dimension ( mm ) | W | 600 | 900 | 1000 | 1200 | 600 | 900 | 1000 | 1200 | 600 | 900 | 1000 | 1200 | |
H | 1500 | 1800 | 2000 | 2100 | 1500 | 1800 | 2000 | 2100 | 1500 | 1800 | 2000 | 2100 | ||
D | 1350 | 1666 | 1770 | 2070 | 1350 | 1666 | 1770 | 2070 | 1350 | 1666 | 1770 | 2070 | ||
Temperature Range ( ℃ ) | -20 ~150 | -40 ~150 | -70 ~150 | |||||||||||
Humidity Range (%RH) | (20 ~98)%RH (20 ~85) ℃ | |||||||||||||
Temperature Fluctuation ( ℃ ) | ±0.5 ℃ | |||||||||||||
Temperature Deviation ( ℃ ) | ±2.0 ℃ | |||||||||||||
Humidity Deviation (%RH) | ±3.0%RH ( >75%RH) ±5.0%RH ( ≤75 %RH) | |||||||||||||
Temperature Rise Time | -20 ~150 ℃ | -40 ~150 ℃ | -70 ~150 ℃ | |||||||||||
≤ 35min | ≤ 40min | ≤ 55min | ≤ 60min | ≤ 35min | ≤ 40min | ≤ 55min | ≤ 60min | ≤ 45min | ≤ 45min | ≤ 60min | ≤ 80min | |||
Temperature Fall Time | +20 ~-20 ℃ | +20 ~-40 ℃ | +20 ~-70 ℃ | |||||||||||
≤ 40min | ≤ 40min | ≤ 40min | ≤ 40min | ≤ 60min | ≤ 60min | ≤ 60min | ≤ 60min | ≤ 80min | ≤ 80min | ≤ 80min | ≤ 80min | |||
Temperature and Humidity Regulation Mode | BTHC Balanced temperature and humidity control mode ( SSR humidity regulation ) | |||||||||||||
Operating Environment | Temperature: (5 ~36) ℃ Humidity : (30 ~85 )%RH Pressure: (86 ~106)kPa ; Temperature: (5 ~36) ℃ Humidity : ( 30 ~85)%RH Pressure: (86 ~106 )kPa | |||||||||||||
Material |
Inner Chamber | Stainless steel sheet SS304 | ||||||||||||
Outer Chamber | Two-sided galvanized plate, with the surface treated by electrostatic powder coating | |||||||||||||
Thermal Insulation | High temperature fibre cotton & polyurethane foam | |||||||||||||
Actuator | Fan | Extended shaft centrifugal fan | ||||||||||||
CompressorRefrigerator | Low- noise piston type compressor or scroll compressor | |||||||||||||
Heater | Imported nickel-chrome heating wire; Imported nickel-chrome | |||||||||||||
Humidifier b | 316 stainless steel humidifier (external steam generator ) | |||||||||||||
Controller System |
Touch Screen & PLC | 7.0 ", 800×480 resolution, mixed output PLC ; 7.0", 800×480 resolution, mixed output PLC | ||||||||||||
Running Mode | Fixed mode , Program mode | |||||||||||||
Setting Mode | Simplified Chinese + English , input by touch; Simplified Chinese & English, input by touch | |||||||||||||
Program Capacity | 269 groups of programs, each consisting of 50 sections for setting 32000 times of cycles. The program has link function | |||||||||||||
Setting Range | Can be adjusted to ±5.0 ℃ according to the maximum range of the equipment , Eg. humidity range (5 ~100 )%RH ( humidity equipment ) | |||||||||||||
Display Resolution | Temperature: 0.01 ℃ , humidity: 0.1%RH ( humidity equipment ) , time: s ; Temperature: 0.01 ℃ , humidity: 0.1%RH (humidity equipment), time: s | |||||||||||||
Sensor | PT100 (platinum resistor) , temperature sensor; PT100 (platinum resistor) , Humidity sensor | |||||||||||||
Control Mode | Low-temperature cold balance & anti- integral saturation PID & auto- tuning | |||||||||||||
Curve Record | With automatic data storage function. User can browse the data by sliding on the screen; screen shot function is available. | |||||||||||||
Additional Function | Fault alarm and cause handling prompt function: Timed startup /stop, power failure protection, user permission function. | |||||||||||||
Communication Function | Support RS485 , LAN ( internet port ) , GPRS ( phone ) and other communication modes, which enable users to conduct remote monitoring simply. Data acquisition: IBM PC compatible machine. CPU above PII, memory above 128M, operating system in Simplified Chinese / English . | |||||||||||||
Data Acquisition | 1. Equipped with USB interface, it can save 3 months of curve data and download historical curves and historical data; 2. It can replace the recorder, with built-in large storage space, and can save 3 months of data if it is turned on for 24 hours continuously. The sampling time is 1 minute, which can replace computer storage. Users can export historical data with a USB flash drive ( time is optional ) and generate CSV format files; 3. Connect to PC ( optional ) - record test data through computer monitoring software, and display curves. PC can be used as a remote terminal to realize remote monitoring. 1. With USB interface, curve data of three months can be saved, and historical curve and test data can be downloaded. 2. It can be an alternative to the recorder. With built-in extra memory, 3 months of data under the condition that the machine runs for 24 hours continuously can be saved. The sampling time is 1min. computer monitoring software. It can display the curve. PC can be used as remote terminal to realize remote monitoring. |
|||||||||||||
Water Supply | Water Supply Mode | Draw water by water pump | ||||||||||||
Water Storage Tank | 10L/20L/40L | |||||||||||||
Water Quality | Resistivity >500 Ω · m | |||||||||||||
Power Supply (V)/(Hz) | AC voltage 380V±38V Frequency 50Hz±0.5Hz 3-phase 4-wire & earthing protection | |||||||||||||
Maximum Current ( A ) | 10 | 13 | 14 | twenty four | 10 | 13 | 14 | 25 | 13 | 18 | twenty one | 38 | ||
Power ( kW ) | 4 | 6 | 6 | 11 | 4.5 | 6.5 | 7 | 12 | 5 | 8 | 12 | 18 | ||
Weight ( kg ) | 145 | 200 | 530 | 760 | 145 | 205 | 540 | 800 | 165 | 245 | 600 | 900 | ||
Standard Configuration | 1 Electric heating observation window , 1 testing hole of Φ50 respectively on each side, 2 sets of sample holders , 4 casters ; 1 Electric heating observation window, 1 testing hole of Φ50 respectively on each side, 2 sets of sample holders, 4 casters | |||||||||||||
Safety Device | Leakage switch, motor, compressor, phase sequence, over-temperature protection , dry burn protection. etc. |
|||||||||||||
a H : Refers to the humidity function is available. b, c: This option is only for temperature & humidity test chamber. d : Circulating water cooling option is selected. Notes: 1. A Refers to fresh air cooling, W refers to circulating water cooling . 2. Freezing point series of test chambers can be customized according to clients' requirements. a H: Refers to the humidity function is available. b, c: This option is only for temperature & humidity test chamber. d: Circulating water cooling option is selected. Notes: 1. A Refers to fresh air cooling, W refers to circulating water cooling. 2. Freezing point series of test chambers can be customized according to clients' requirements. |
REFRIGERATED SYSTEM:
●Adopt imported components & parts from famous internal brands
●Adopt R404A and R23 refrigerant with the ozone depletion factor of 0
●All condensers are installed with filtration device, which ensures long-term reliable operation of the unit
●Intelligent control of refrigeration system applies to large range of load and the running power is lower
●Imported compressor: Copeland, Bock or Bizter, low in noise , stable in operation and powerful in performance
●Before welding, all pipelines shall be charged with nitrogen to protect the interior of the copper part from oxidation. The weld junction is sprayed with varnish for protection. The company is one of the manufactures up to this standard
●Refrigeration unit adopts modular production, including sub-assembly, part assembly and general assembly; set up the elbow manual guarantees the uniformity of the system; standardized modules are convenient to install, debug and maintain
CONTROL SYSTEM:
● Integrated design of air supply channel and refrigeration unit.
● Large size observation window makes it convenient for operator to observe the test sample inside the chamber.
● The inner chamber is made by SUS304 stainless steel; the external chamber is made by two-sided galvanized steel sheet and its surface is treated by electrostatic plastic spraying.
● The refrigerating system, waterway system and the electrical control system of the chamber have been modularized, placed separately and are safe and reliable.
● Intelligent control of refrigeration system applies to large range of load and the running power is lower.
REVIEWS
Tell us what you think about this product, share your opinion with other people. Please make sure that your review focus on the product. Inappropriate reviews will not be posted.
INQUIRY
Should you need more information on the product, kindly write your details to us.
FOLLOW US